Concealed soffit slat system

This installation system is available for 5/16” (8 mm) thick panels and the following standard slat widths: 7 3/8” (188 mm) and 11 3/8” (290 mm). For other sizes, contact Prodema.

These are the available subframe and items for the installation: fixing clip, screws (for the fixing clip, for the final row of the soffit, for the fixed point), Js and Hats channels, L and T channels and wall brackets.

These are installation requirements:

  • Keep between 3/4” and 1/2” (20 and 40mm) of distance from the fixing clip to the edge of the panel.
  • This system requires fasteners every 24” (600 mm).
  • In pieces wider than 12” (300 mm) 3 supporting points are required in every sense.
  • Use the following items for their purpose:
    • Use the gauge tool for the expansion joint between boards.
    • Add 1 fixed point in the middle of the panel.
    • Finish the final row of the soffit with the specific screws taking into account the fixed and floating point rules as recommended on the technical catalogue of ProdEx.
    • Use a washer to keep the last panel straight.

Shop Drawings

We develop your project's master blueprints, guaranteeing the certainty of proper installation.

Request Shop Drawing service